    "id": "lc_tab",
    "type": "tab",
    "label": "KNX Load Control",
    "disabled": false,
    "info": ""
  },
  {
    "id": "lc_cfg",
    "type": "knxUltimate-config",
    "z": "",
    "host": "224.0.23.12",
    "port": "3671",
    "physAddr": "15.15.216",
    "suppressACKRequest": false,
    "csv": "",
    "KNXEthInterface": "Auto",
    "KNXEthInterfaceManuallyInput": "",
    "autoReconnect": "no"
  },
  {
    "id": "lc_c",
    "type": "comment",
    "z": "lc_tab",
    "name": "Manual shedding/unshedding with 5 priority loads",
    "info": "",
    "x": 430,
    "y": 60,
    "wires": []
  },
  {
    "id": "lc_node",
    "type": "knxUltimateLoadControl",
    "z": "lc_tab",
    "server": "lc_cfg",
    "name": "Load Control",
    "controlMode": "msg",
    "topic": "4/0/1",
    "dpt": "14.056",
    "wattLimit": 3000,
    "sheddingCheckInterval": 15,
    "sheddingRestoreDelay": 60,
    "GA1": "4/1/1",
    "DPT1": "1.001",
    "Name1": "Water Heater",
    "autoRestore1": true,
    "MonitorGA1": "4/2/1",
    "MonitorDPT1": "14.056",
    "MonitorName1": "Water Heater W",
    "GA2": "4/1/2",
    "DPT2": "1.001",
    "Name2": "EV Charger",
    "autoRestore2": true,
    "MonitorGA2": "4/2/2",
    "MonitorDPT2": "14.056",
    "MonitorName2": "EV Charger W",
    "GA3": "4/1/3",
    "DPT3": "1.001",
    "Name3": "Boiler",
    "autoRestore3": true,
    "MonitorGA3": "4/2/3",
    "MonitorDPT3": "14.056",
    "MonitorName3": "Boiler W",
    "GA4": "4/1/4",
    "DPT4": "1.001",
    "Name4": "Dryer",
    "autoRestore4": true,
    "MonitorGA4": "4/2/4",
    "MonitorDPT4": "14.056",
    "MonitorName4": "Dryer W",
    "GA5": "4/1/5",
    "DPT5": "1.001",
    "Name5": "Oven",
    "autoRestore5": true,
    "MonitorGA5": "4/2/5",
    "MonitorDPT5": "14.056",
    "MonitorName5": "Oven W",
    "x": 690,
    "y": 240,
    "wires": [
      [
        "lc_dbg"
      ]
    ]
  },
  {
    "id": "lc_shed",
    "type": "inject",
    "z": "lc_tab",
    "name": "msg.shedding = shed",
    "props": [
      {
        "p": "shedding",
        "v": "shed",
        "vt": "str"
      }
    ],
    "repeat": "",
    "crontab": "",
    "once": false,
    "onceDelay": 0.1,
    "x": 210,
    "y": 200,
    "wires": [
      [
        "lc_node"
      ]
    ]
  },
  {
    "id": "lc_unshed",
    "type": "inject",
    "z": "lc_tab",
    "name": "msg.shedding = unshed",
    "props": [
      {
        "p": "shedding",
        "v": "unshed",
        "vt": "str"
      }
    ],
    "repeat": "",
    "crontab": "",
    "once": false,
    "onceDelay": 0.1,
    "x": 220,
    "y": 240,
    "wires": [
      [
        "lc_node"
      ]
    ]
  },
  {
    "id": "lc_auto",
    "type": "inject",
    "z": "lc_tab",
    "name": "msg.shedding = auto",
    "props": [
      {
        "p": "shedding",
        "v": "auto",
        "vt": "str"
      }
    ],
    "repeat": "",
    "crontab": "",
    "once": false,
    "onceDelay": 0.1,
    "x": 210,
    "y": 280,
    "wires": [
      [
        "lc_node"
      ]
    ]
  },
  {
    "id": "lc_dbg",
    "type": "debug",
    "z": "lc_tab",
    "name": "Load control output",
    "active": true,
    "tosidebar": true,
    "console": false,
    "tostatus": true,
    "complete": "true",
    "targetType": "full",
    "x": 950,
    "y": 240,
    "wires": []
  }
]